Home | About JCVJS | Editorial board | Ahead of print | Current Issue | Archives | Instructions | Subscribe | Advertise | Contact us |   Login 
Journal of Craniovertebral Junction and Spine
Search Articles   
    
Advanced search   
 
ORIGINAL ARTICLE
Year : 2018  |  Volume : 9  |  Issue : 2  |  Page : 116-121

Cadaveric device-injected very high-viscosity cement during vertebroplasty


1 Department of Orthopedic Surgery, King Saud University, Riyadh, Saudi Arabia
2 Department of Orthopaedic Surgery, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Republic of Korea
3 Department of Orthopedic Surgery, Orthopaedic Research Laboratory, McGill University, Montreal, Canada
4 McGill University Health Centre, McGill University, Montreal, Canada

Correspondence Address:
Dr. Abdulrahman D Algarni
Department of Orthopedic Surgery, King Saud University, Riyadh
Saudi Arabia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcvjs.JCVJS_143_17

Rights and Permissions

Introduction: Cement extravasation during vertebroplasty (VP) is the most commonly reported complication. Cement viscosity is considered the single most important predictor of the risk of extravasation. Certainly, injecting high-viscosity cement (HVC) is difficult to utilize in real practice. We invented a new device capable of injecting high-viscosity with ease and at a distance to avoid radiation. The aim of this study is to confirm the efficacy and safety of the new device on cadaveric vertebrae. Methodology: A 126 osteoporotic vertebral bodies were harvested from cadavers. Eighty vertebrae were included in the study. Computer-randomization software was used to allocate specimens over two main groups, Conventional VP and New Device. Both groups were further subdivided into two subgroups; high-viscosity and low-viscosity. A custom device was used on each vertebra to induce a compression fracture. Results: Injecting HVC was associated with a lower leakage volume compared with low-viscosity cement. HVC was associated with no leakage into the spinal canal. It was also associated with a low incidence of vascular extravasation (P < 0.001). The mean volume of cement leakage in the low-viscosity group was 0.23 and 0.15 cc, for the Conventional VP and New Device, respectively. In both groups, the most common site for leakage was the vertebral end plate, which was exhibited more in the low-viscosity group (71.5%) compared with the high-viscosity group (42.5%). The preset target amount of cement to be injected was reached in 99% of the time when injecting HVC with the New Device, compared with 62% using the Conventional VP. In both groups, there was no correlation between the amount of cement injected and the amount of leakage. Conclusion: The new device is capable of injecting HVC easily, with a lower incidence of cement leakage. It also minimized the risk of radiation exposure to the surgeon.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3425    
    Printed105    
    Emailed0    
    PDF Downloaded93    
    Comments [Add]    

Recommend this journal