Home | About JCVJS | Editorial board | Ahead of print | Current Issue | Archives | Instructions | Subscribe | Advertise | Contact us |   Login 
Journal of Craniovertebral Junction and Spine
Search Articles   
    
Advanced search   
 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 12  |  Issue : 4  |  Page : 381-386

Safety, efficacy, surgical, and radiological outcomes of short segment occipital plate and C2 transarticular screw construct for occipito-cervical instability


Department of Orthopaedics, Bombay Hospital and Medical Research Centre, Mumbai, Maharashtra, India

Correspondence Address:
Praveen V. N. R. Goparaju
Bombay Hospital and Medical Research Centre, Mumbai, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcvjs.jcvjs_113_21

Rights and Permissions

Objective: Our study aims to assess the safety, efficacy, clinicoradiological, functional, neurological outcomes, and complications of posterior occipitocervical fixation using an occipital plate and C1-2 transarticular screw (TAS) construct. Study Design: This was a retrospective analysis of prospectively collected data. Methods: Data of 27 patients who underwent occipital plate and C1-2 TAS construct at a single institute from 2010 to 2015 were collected and analyzed. Demographics, clinical parameters (Visual Analog Score, Oswestry Disability Index, and modified JOA score), radiological parameters – mean atlantodens interval, posterior occipitocervical angle, occipitocervical-2 angle, surgical parameters (operative time, blood loss, hospital stay, and fusion), and complications were evaluated. Results: The mean age of the patients was 54.074 ± 16.52 years (18–81 years), the mean operative time was 116.29 ± 12.23 min, and the mean blood loss was 196.29 ± 38.94 ml. The mean hospital stay was 5.22 ± 1.28 days. The mean ± standard deviation follow-up duration was 62.52 ± 2.27 months. There was a significant improvement in clinical parameters and radiological parameters postoperatively. One patient with implant failure, one patient with pseudoarthrosis, one with neurological deterioration, two wound complications, and two dural tears were noted. Conclusion: Posterior occipitocervical reconstruction with O-C1-2 TAS construct provided excellent clinical outcomes, radiological outcomes, optimal correction of malalignment in the occipitocervical region, and with biomechanically sound fixation. Extending the instrumentation into the subaxial spine will lead to a decrease in the range of motion, increased surgical time, blood loss, more extensive muscle damage, and also increase the costs.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed291    
    Printed4    
    Emailed0    
    PDF Downloaded32    
    Comments [Add]    

Recommend this journal